Manholes «Spiroplast»

 

 

Wells plant «Spiroplast» compatible with various types of pipes.

 

 

The wells are easy to install. In the factory they have formed part of the flume with the required slope, which provides hydraulic smoothness, which contributes to an outflow of dirt and prevents clogging and silting of the well.

 

 

 

 

 

Well of sewer line inspection Spiro KILK – 01.01

 

 

 

 

Well diameter, Dk, mm

Pipes diameter mm

Main body height, Н, mm

Input pipe

dy1

Output pipe dy2

700

150

150

900

1000

150

150

900-2100

200

200

900-2100

250

250

900-2100

300

300

900-2100

350

350

900-2100

400

400

900-2100

450

450

900-2100

500

500

900-2100

600

600

900-2100

1500

600

600

900-2100

700

900-2100

800

900-2100

700

700

900-2100

800

900-2100

900

900-2100

800

800

900-2100

900

900-2100

1000

900-2100

900

900

900-2100

1000

900-2100

2000

1000

1200

900-2100

1200

1200

900-2100

 

 

 

Turning sewage inspection pit Spiro KILK – 01.02

 

 

 

 

Well diameter, Dk, mm

Pipe diameter, dy, mm

Turn angle, ąº

Main body height, Н, mm

700

150

15-90

900

1000

150

15-90

900-2100

200

15-90

900-2100

250

15-90

900-2100

300

15-90

900-2100

350

15-90

900-2100

1500

400

15-90

900-2100

450

15-90

900-2100

500

15-90

900-2100

600

15-90

900-2100

700

15-90

900-2100

2000

800

15-90

900-2100

900

15-90

900-2100

1000

15-60

900-2100

 

 

 

Sewer inspection pit nodal SPIRO KIU1K – 01.03

 

 

 

 

 

Well diameter, Dk, mm

Pipe diameter, mm

Main body height, Н, mm

Input pipe

dy1

Connected pipe

dy2

Output pipe dy3

700

150

150

200

900

1000

150

150

200

900-2100

200

150-200

250-300

900-2100

250

150-250

300-350

900-2100

300

150-300

350-400

900-2100

350

150-350

400-450

900-2100

400

150-300

450-500

900-2100

1500

400

350-450

600-500

900-2100

450

200-450

500-600

900-2100

500

150-500

500-700

900-2100

600

150-300

600-700

900-2100

2000

600

350-500

800

900-2100

700

250-500

800-900

900-2100

800

150-500

800-1000

900-2100

900

150-500

900-1000

900-2100

1000

150-500

1000-1200

900-2100

1200

150-500

1200

900-2100

 

 

 

 

Sewer inspection pit nodal SPIRO KIU2K- 01.04

 

 

 

Well diameter, Dk, mm

Pipe Diameter, mm

Main body height, Н, mm

Input pipe

dy1

Connected pipe

dy2

Output pipe dy3

700

150

150

250

900

1000

150

150

250

900-2100

200

150-200

300-350

900-2100

250

150-200

350-450

900-2100

300

150-300

350-500

900-2100

350

150-350

400-600

900-2100

400

150-400

500-700

900-2100

450

150-400

500-700

900-2100

2000

450

450

800

900-2100

1500

500

150-350

600-700

900-2100

2000

500

400-500

800-900

900-2100

1500

600

150-200

700

900-2100

2000

600

250-500

700-900

900-2100

1500

700

150-500

700-1000

900-2100

800

150-500

800-1000

900-2100

900

150-400

900-1000

900-2100

1000

150-200

1000

900-2100

1200

150-200

1200

900-2100

 

 

Well of audit sewer Spiro KRK – 01.05

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Well diameter

Dk, mm

Pipe diameter

dy, mm

h2, mm

400

110÷250

300

500

110÷300

300

600

110÷400

300

700

110÷450

300

800

110÷500

300

 

 

Well of sewer sediment SPIRO KOK- 01.06

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 Well diameter,Dk, mm

Pipe diameter, dn, mm

h2, mm

Vos, dm3

400

110

350

40

160

200

500

110

600

70

160

200

250

600

110

250

70

160

200

250

300

315

700

110

700

200

160

200

250

300

315

355

800

110

800

200

160

200

250

300

315

355

400

900

110

900

200

160

200

250

300

315

355

400

450

1000

110

1000

200

160

200

250

300

315

355

400

450

500

 

 

The well maintained gauging SPIRO KOB – 01.07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Well diameter

Dk, mm

Pipe diameter

dy, mm

h2, mm

1000

32÷75

500

1200

32÷110

500

1400

32÷315

500

2000

32÷630

500

 

 

 

Well of special sewer line type “1” SPIRO KLSK-1.8.01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Well diameter, mm

Pipe diameter

dy, mm

400

400÷500

600

600÷700

800

800÷900

1000

1000÷1200

 

 

 

Well of special sewer line type “2” SPIRO KLSK-1.8.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Well diameter

Dk, mm

Pipe diameter

dy, mm

600

300

800

500

1000

700

1200

900

 

 

Well of eccentric sewage SPIRO KEK – 01.09

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Well diameter

Dk, mm

Pipe diameter

dy,mm

1000

700÷2200

1200

700÷2200

1400

900÷2200

* – Angle intake: 0 ° ¸ 180 °

 

 

 

Installation of manholes «Spiroplast»

 

Manholes «Spiroplast» can be installed both at low and at great depth on stable ground, and on unstable soils with a high water table, in areas with a risk of damage caused by mining activities or on the ground, carrying the dynamic loads from traffic .

 

 

 

When the trench is necessary to pay attention not to the weakening of the global excess soil, and not to exceed a certain depth.

 

The trench should be at 0.15 m deep and about 0.6 m wider than the outside diameter of the well. Trench bottom should fill with sand to a height of 0.15 m and seal.

 

Depending on the level of ground water well can be equipped with a camera overhead. The standard height of the overhead camera is 0.3 m

 

Additional load cell should be filled with concrete. To do this, at the bottom of the bottom two are located on opposite sides, through which the pipe is filled with concrete.

 

After filling with concrete pipes, close the plastic cover.

 

 

Installation of manholes «Spiroplast» wet soils

When the trench is necessary to pay attention not to the weakening of the global excess soil, and not to exceed a certain depth.

 

 

 

The trench should be at 0.15 m deep and about 0.6 m wider than the outside diameter of the well. Trench bottom should fill with sand to a height of 0.15 m and seal.

 

Depending on the level of ground water well can be equipped with a camera overhead. The standard height of the overhead camera is 0.3 m

 

 

 

Additional load cell should be filled with concrete. To do this, at the bottom of the bottom two are located on opposite sides, through which the pipe is filled with concrete.

 

After filling with concrete pipes, close the plastic cover.

 

 

Installation of manholes «Spiroplast» wet soils

 

Before installation of wells «Spiroplast» in flooded soils is necessary to stabilize the soil under them, such as a concrete slab.

 

 

 

The well placed at bottom of the trench, given the direction of input and output lines and slope channel.

 

The degree of compaction of soil around the well, and the type of soil used for the deposition of the well is determined by the local land and soil conditions, traffic loads and design coverage.

 

 

To perform bedding, sprinkled and backfill can be used gravel, sand, sand-gravel mixture. For ground sprinkled do not use thick organic soils. In the case of on-site installation of ground in this group, the soils to replace the well sprinkled loose soil.

 

 

Depending on the level of ground water well can be supplied to a ballast down.

The standard height of the ballast bed h = 0,3 m

Ballast bed filled concrete. For these purposes, the bottom of the ballast holds two pipes to pump concrete. After pumping concrete pipes fitting lid.

 

 

 

Order form can be downloaded here wells

 

 

Reservoirs «Spiroplast»

 

Plant «Spiroplast» produces a wide range of tanks made of polyethylene and polypropylene, for storage and settling various liquids:

 

 

 

 

– Drinking water and rainwater;

– Fire Water;

– Municipal waste water;

– Waste from landfills;

– Runoff of agricultural origin: manure, ground water, silage effluent;

– Very aggressive wastewater to sewage treatment plants and industrial plants.

 

The tanks are made of pipes spirit.

 

The range of diameters of pipes used Spiro from 1000 to 3000 mm.

The tanks can be installed underground or on the surface, horizontal or vertical, with any bias.

 

The tanks of the plant «Spiroplast»:

– Completely sealed;

– Safe and durable;

– Resistant to corrosive wastewater;

– Have relatively low weight;

– Easy to transport;

– Easy to install;

– Ready for use immediately after installation.

 

 

 

Spiro reservoir horizontal RG-02.01-1000/V2

 

 

 

 

 

1 – tube filler, 2 – neck, 3 – body, 4 – ventilation outlet, 5 – tube feeding.

 

 

 

 

 

 

 

 

 

 

 

 


Reservoir model

V=Vn

Dn

Lp

m3

mm

mm

SPIRO RG-02.01-1000/V2

2

1000

2700

SPIRO RG-02.01-1000/V3

3

1000

3900

SPIRO RG-02.01-1000/V5

5

1000

6500

SPIRO RG-02.01-1000/V8

8

1000

10300

SPIRO RG-02.01-1000/V10

10

1000

12800

SPIRO RG-02.01-1200/V3

3

1200

2800

SPIRO RG-02.01-1200/V5

5

1200

4600

SPIRO RG-02.01-1200/V8

8

1200

7200

SPIRO RG-02.01-1200/V10

10

1200

9000

SPIRO RG-02.01-1200/V12

12

1200

10800

SPIRO RG-02.01-1200/V15

15

1200

13400

SPIRO RG-02.01-1400/V3

3

1400

2200

SPIRO RG-02.01-1400/V5

5

1400

3500

SPIRO RG-02.01-1400/V8

8

1400

5500

SPIRO RG-02.01-1400/V10

10

1400

6700

SPIRO RG-02.01-1400/V12

12

1400

8100

SPIRO RG-02.01-1400/V15

15

1400

10000

SPIRO RG-02.01-1400/V18

18

1400

12000

SPIRO RG-02.01-1400/V20

20

1400

13300

SPIRO RG-02.01-1600/V5

5

1600

2800

SPIRO RG-02.01-1600/V8

8

1600

4300

SPIRO RG-02.01-1600/V10

10

1600

5300

SPIRO RG-02.01-1600/V12

12

1600

6300

SPIRO RG-02.01-1600/V15

15

1600

7800

SPIRO RG-02.01-1600/V18

18

1600

9300

SPIRO RG-02.01-1600/V20

20

1600

10300

SPIRO RG-02.01-1600/V25

25

1600

12800

SPIRO RG-02.01-1800/V8

8

1800

3400

SPIRO RG-02.01-1800/V10

10

1800

4200

SPIRO RG-02.01-1800/V12

12

1800

5000

SPIRO RG-02.01-1800/V15

15

1800

6200

SPIRO RG-02.01-1800/V18

18

1800

7300

SPIRO RG-02.01-1800/V20

20

1800

8100

SPIRO RG-02.01-1800/V25

25

1800

10100

SPIRO RG-02.01-1800/V30

30

1800

12100

SPIRO RG-02.01-1800/V35

35

1800

14000

SPIRO RG-02.01-2000/V10

10

2000

3500

SPIRO RG-02.01-2000/V12

12

2000

4100

SPIRO RG-02.01-2000/V15

15

2000

5100

SPIRO RG-02.01-2000/V18

18

2000

6100

SPIRO RG-02.01-2000/V20

20

2000

6700

SPIRO RG-02.01-2000/V25

25

2000

8300

SPIRO RG-02.01-2000/V30

30

2000

9900

SPIRO RG-02.01-2000/V35

35

2000

11500

SPIRO RG-02.01-2000/V40

40

2000

13100

SPIRO RG-02.01-2200/V12

12

2200

3600

SPIRO RG-02.01-2200/V15

15

2200

4400

SPIRO RG-02.01-2200/V18

18

2200

5200

SPIRO RG-02.01-2200/V20

20

2200

5700

SPIRO RG-02.01-2200/V25

25

2200

7000

SPIRO RG-02.01-2200/V30

30

2200

8300

SPIRO RG-02.01-2200/V35

35

2200

9700

SPIRO RG-02.01-2200/V40

40

2200

11000

SPIRO RG-02.01-2200/V45

45

2200

12300

SPIRO RG-02.01-2200/V50

50

2200

13600

SPIRO RG-02.01-2400/V15

15

2400

3400

SPIRO RG-02.01-2400/V18

18

2400

4100

SPIRO RG-02.01-2400/V20

20

2400

4500

SPIRO RG-02.01-2400/V25

25

2400

5600

SPIRO RG-02.01-2400/V30

30

2400

6700

SPIRO RG-02.01-2400/V35

35

2400

7800

SPIRO RG-02.01-2400/V40

40

2400

8900

SPIRO RG-02.01-2400/V45

45

2400

10000

SPIRO RG-02.01-2400/V50

50

2400

11100

SPIRO RG-02.01-2400/V60

60

2400

13300

SPIRO RG-02.01-2600/V20

20

2600

4200

SPIRO RG-02.01-2600/V25

25

2600

5200

SPIRO RG-02.01-2600/V30

30

2600

6100

SPIRO RG-02.01-2600/V35

35

2600

7100

SPIRO RG-02.01-2600/V40

40

2600

8000

SPIRO RG-02.01-2600/V45

45

2600

8900

SPIRO RG-02.01-2600/V50

50

2600

9900

SPIRO RG-02.01-2600/V60

60

2600

11800

SPIRO RG-02.01-2600/V70

70

2600

13600

SPIRO RG-02.01-2800/V25

25

2800

4200

SPIRO RG-02.01-2800/V30

30

2800

5000

SPIRO RG-02.01-2800/V35

35

2800

5800

SPIRO RG-02.01-2800/V40

40

2800

6600

SPIRO RG-02.01-2800/V45

45

2800

7400

SPIRO RG-02.01-2800/V50

50

2800

8200

SPIRO RG-02.01-2800/V60

60

2800

9900

SPIRO RG-02.01-2800/V70

70

2800

11500

SPIRO RG-02.01-2800/V80

80

2800

13100

SPIRO RG-02.01-3000/V30

30

3000

4700

SPIRO RG-02.01-3000/V35

35

3000

5300

SPIRO RG-02.01-3000/V40

40

3000

6100

SPIRO RG-02.01-3000/V45

45

3000

6800

SPIRO RG-02.01-3000/V50

50

3000

7500

SPIRO RG-02.01-3000/V60

60

3000

8900

SPIRO RG-02.01-3000/V70

70

3000

10300

SPIRO RG-02.01-3000/V80

80

3000

11800

SPIRO RG-02.01-3000/V90

90

3000

13200

 

 

Tank, vertical Spiro RV-02.02-2000/V25

 

 

 

 

 

 

 

1 – neck, 2 – pipe filler, 3 – housing, 4 – pipe overflow, 5 – tube feeding, 6 – nipple discharge.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reservoir model

V=Vn

Dn

Lp

m3

mm

mm

SPIRO RV-02.02-1000/V2

2

1000

2700

SPIRO RV-02.02-1000/V3

3

1000

3900

SPIRO RV-02.02-1000/V5

5

1000

6500

SPIRO RV-02.02-1000/V8

8

1000

10300

SPIRO RV-02.02-1000/V10

10

1000

12800

SPIRO RV-02.02-1200/V3

3

1200

2800

SPIRO RV-02.02-1200/V5

5

1200

4600

SPIRO RV-02.02-1200/V8

8

1200

7200

SPIRO RV-02.02-1200/V10

10

1200

9000

SPIRO RV-02.02-1200/V12

12

1200

10800

SPIRO RV-02.02-1200/V15

15

1200

13400

SPIRO RV-02.02-1400/V3

3

1400

2200

SPIRO RV-02.02-1400/V5

5

1400

3500

SPIRO RV-02.02-1400/V8

8

1400

5500

SPIRO RV-02.02-1400/V10

10

1400

6700

SPIRO RV-02.02-1400/V12

12

1400

8100

SPIRO RV-02.02-1400/V15

15

1400

10000

SPIRO RV-02.02-1400/V18

18

1400

12000

SPIRO RV-02.02-1400/V20

20

1400

13300

SPIRO RV-02.02-1600/V5

5

1600

2800

SPIRO RV-02.02-1600/V8

8

1600

4300

SPIRO RV-02.02-1600/V10

10

1600

5300

SPIRO RV-02.02-1600/V12

12

1600

6300

SPIRO RV-02.02-1600/V15

15

1600

7800

SPIRO RV-02.02-1600/V18

18

1600

9300

SPIRO RV-02.02-1600/V20

20

1600

10300

SPIRO RV-02.02-1600/V25

25

1600

12800

SPIRO RV-02.02-1800/V8

8

1800

3400

SPIRO RV-02.02-1800/V10

10

1800

4200

SPIRO RV-02.02-1800/V12

12

1800

5000

SPIRO RV-02.02-1800/V15

15

1800

6200

SPIRO RV-02.02-1800/V18

18

1800

7300

SPIRO RV-02.02-1800/V20

20

1800

8100

SPIRO RV-02.02-1800/V25

25

1800

10200

SPIRO RV-02.02-1800/V30

30

1800

12100

SPIRO RV-02.02-1800/V35

35

1800

14000

SPIRO RV-02.02-2000/V10

10

2000

3500

SPIRO RV-02.02-2000/V12

12

2000

4100

SPIRO RV-02.02-2000/V15

15

2000

5100

SPIRO RV-02.02-2000/V18

18

2000

6100

SPIRO RV-02.02-2000/V20

20

2000

6700

SPIRO RV-02.02-2000/V25

25

2000

8300

SPIRO RV-02.02-2000/V30

30

2000

9900

SPIRO RV-02.02-2000/V35

35

2000

11500

SPIRO RV-02.02-2000/V40

40

2000

13100

SPIRO RV-02.02-2200/V12

12

2200

3600

SPIRO RV-02.02-2200/V15

15

2200

4400

SPIRO RV-02.02-2200/V18

18

2200

5200

SPIRO RV-02.02-2200/V20

20

2200

5700

SPIRO RV-02.02-2200/V25

25

2200

7000

SPIRO RV-02.02-2200/V30

30

2200

8300

SPIRO RV-02.02-2200/V35

35

2200

9700

SPIRO RV-02.02-2200/V40

40

2200

11000

SPIRO RV-02.02-2200/V45

45

2200

12300

SPIRO RV-02.02-2200/V50

50

2200

13600

SPIRO RV-02.02-2400/V15

15

2400

3400

SPIRO RV-02.02-2400/V18

18

2400

4100

SPIRO RV-02.02-2400/V20

20

2400

4500

SPIRO RV-02.02-2400/V25

25

2400

5600

SPIRO RV-02.02-2400/V30

30

2400

6700

SPIRO RV-02.02-2400/V35

35

2400

7800

SPIRO RV-02.02-2400/V40

40

2400

8900

SPIRO RV-02.02-2400/V45

45

2400

10000

SPIRO RV-02.02-2400/V50

50

2400

11100

SPIRO RV-02.02-2400/V60

60

2400

13300

SPIRO RV-02.02-2600/V20

20

2600

4200

SPIRO RV-02.02-2600/V25

25

2600

5200

SPIRO RV-02.02-2600/V30

30

2600

6100

SPIRO RV-02.02-2600/V35

35

2600

7100

SPIRO RV-02.02-2600/V40

40

2600

8000

SPIRO RV-02.02-2600/V45

45

2600

8900

SPIRO RV-02.02-2600/V50

50

2600

9900

SPIRO RV-02.02-2600/V60

60

2600

11800

SPIRO RV-02.02-2600/V70

70

2600

13600

SPIRO RV-02.02-2800/V25

25

2800

4200

SPIRO RV-02.02-2800/V30

30

2800

5000

SPIRO RV-02.02-2800/V35

35

2800

5800

SPIRO RV-02.02-2800/V40

40

2800

6600

SPIRO RV-02.02-2800/V45

45

2800

7400

SPIRO RV-02.02-2800/V50

50

2800

8200

SPIRO RV-02.02-2800/V60

60

2800

9900

SPIRO RV-02.02-2800/V70

70

2800

11500

SPIRO RV-02.02-2800/V80

80

2800

13100

SPIRO RV-02.02-3000/V30

30

3000

4700

SPIRO RV-02.02-3000/V35

35

3000

5300

SPIRO RV-02.02-3000/V40

40

3000

6100

SPIRO RV-02.02-3000/V45

45

3000

6800

SPIRO RV-02.02-3000/V50

50

3000

7500

SPIRO RV-02.02-3000/V60

60

3000

8900

SPIRO RV-02.02-3000/V70

70

3000

10300

SPIRO RV-02.02-3000/V80

80

3000

11800

SPIRO RV-02.02-3000/V90

90

3000

13200

 

 

 

Horizontal tank with pump station SPIRO RGNS-2.3

 

 

 

1 – tube filler, 2 – overflow, 3 – drain pipe, 4 – neck, 5 – housing, 6 ¬ – camera pumping station, 7 – tube feeding.

 

 

 

 

 

 

 

 

 

 

 

 

 

Reservoir model

V=Vn

Lv

Dn

Lp

m3

mm

mm

mm

SPIRO RGНС-02.03-1000/V8

8

10300

1000

11800

SPIRO RGНС-02.03-1200/V10

10

9000

1200

11000

SPIRO RGНС-02.03-1400/V15

15

10000

1400

12000

SPIRO RGНС-02.03-1600/V20

20

10300

1600

12300

SPIRO RGНС-02.03-1800/V25

25

10100

1800

12600

SPIRO RGНС-02.03-2000/V30

30

9900

2000

11400

SPIRO RGНС-02.03-2200/V35

35

9700

2200

11200

SPIRO RGНС-02.03-2400/V40

40

8900

2400

11900

SPIRO RGНС-02.03-2600/V45

45

8900

2600

11900

SPIRO RGНС-02.03-2800/V50

50

8200

2800

11700

SPIRO RGНС-02.03-3000/V60

60

8900

3000

12400